[vc_custom_heading text=”Specifications” font_container=”tag:h2|text_align:center” use_theme_fonts=”yes”]
| Type(Cooling) |
| Indoor Unit |
| PLY-SP18EA |
| Outdoor Unit |
| SUY-SA18VA2 |
| Compressor, Refrigerant & Ambient Operations |
|
| Noise Level Indoor (Low/Mid2/Mid1/High) In dB(A) |
28/30/32/35 |
| Noise Level Outdoor In dB(A) |
47 |
| Refrigerant |
R410A |
| Performance Parameters |
|
| Nominal Capacity (Tr) |
1.5 Tr |
| Star Rating – As Per BEE |
5Star |
| Power Supply(Indoor Unit) |
1ph 220-240V 50Hz |
| Power Supply(Outdoor Unit) |
1ph 220-240V 50Hz |
| Cooling Capacity(Min-Max) |
5.3(2.8-5.3)kW |
| Total Input |
1.60kW |
| ISEER (W/W) |
4.50 |
| EER (W/W) |
3.31 |
| Airflow (CFM) (Low/Mid2/Mid1/High)-Indoor |
565/600/670/740 |
| Airflow (CFM)-Outdoor |
953 |
| Guaranteed Operating Range Upper Limit(DB) |
52 |
| Guaranteed Operating Range Lower Limit(DB) |
18 |
| Dimensions & Weight |
|
|
|
| Indoor unit |
Dimensions (H x W x D)(panel) |
mm |
258(40)x840(950)x840(950) |
|
Weight(panel) |
kg |
21(5) |
| Outdoor unit |
Dimensions (H x W x D) |
mm |
550x800x285 |
|
Weight |
kg |
32 |
| Ext.Piping |
Diameter Liquid |
mm (inches) |
6.35 |
|
Diameter Gas |
mm (inches) |
12.7 |
|
Max. piping length |
m |
20 |
|
Max. height difference |
m |
12 |
*Refrigerant piping length (one-way):7.5m(25ft)
*Rating conditions Cooling – Indoor:27C(80F)DB, 19C(66F)WB, Outdoor:35C(95F)DB
| Type (Cooling) |
| Indoor Unit |
| PLY-SP24EA |
| Outdoor Unit |
| SUY-SA24VA2 |
| Performance Parameters |
| Nominal Capacity |
2 Tr |
| Star Rating – As Per BEE |
5 Star |
| Cooling Capacity(Min-Max) |
7.1(2.9-7.1)kW |
| Total Input |
2.17kW |
| Power Supply(Indoor) |
1ph 220-240V 50Hz |
| Power Supply(Outdoor) |
1ph 220-240V 50Hz |
| ISEER(W/W) |
4.50 |
| EER (W/W) |
3.27 |
| Air Flow Volume(CFM)(Low/Med2/Med1/High)-Indoor |
565/635/740/810 |
| Air Flow Volume(CFM)-Outdoor |
1625 |
| Guaranteed Operating Range Upper Limit(DB) |
52 |
| Guaranteed Operating Range Lower Limit(DB) |
18 |
| Compressor, Refrigerant & Ambient Operations |
| Noise Level Indoor (Low/Med2/Med1/High) In dB(A) |
28/31/34/37 |
| Noise Level Outdoor In dB(A) |
52 |
| Refrigerant |
R410A |
| Dimensions & Weight |
| Indoor unit |
Dimensions (H x W x D)(panel) |
mm |
258(40)x840(950)
x840(950)
|
| Weight(panel) |
kg |
21(5) |
| Outdoor unit |
Dimensions (H x W x D) |
mm |
880x840x330 |
| Weight |
kg |
49 |
| Ext.Piping |
Diameter Liquid |
mm (inches) |
9.52 |
| Diameter Gas |
mm (inches) |
15.88 |
| Max Piping length |
m |
30 |
| Max. height difference |
m |
15 |
| Type (Cooling) |
| Indoor Unit |
| PLY-SP30EA |
| Outdoor Unit |
| SUY-SA30VA2 |
| Performance Parameters |
| Nominal Capacity |
2.5 Tr |
| Star Rating – As Per BEE |
5 Star |
| Cooling Capacity(Min-Max) |
8.8(4.1-8.8)kW |
| Total Input |
2.48kW |
| Power Supply(Indoor) |
1ph 220-240V 50Hz |
| Power Supply(Outdoor) |
1ph 220-240V 50Hz |
| ISEER(W/W) |
4.50 |
| EER (W/W) |
3.54 |
| Air Flow Volume (CFM) (Low/Med2/Med1/High)-Indoor |
670/810/920/1025 |
| Air Flow Volume (CFM) -Outdoor |
1800 |
| Compressor, Refrigerant & Ambient Operations |
| Noise Level Indoor (Low/Med2/Med1/High) In dB(A) |
31/34/37/41 |
| Noise Level Outdoor In dB(A) |
54 |
| Refrigerant |
R410A |
| Dimensions & Weight |
| Indoor unit |
Dimensions (H x W x D) |
mm |
298(40)x840(950)
x840(950)
|
| Weight |
kg |
24(5) |
| Outdoor unit |
Dimensions (H x W x D) |
mm |
880x840x330 |
| Weight |
kg |
50 |
| Ext.Piping |
Diameter Liquid |
mm (inches) |
9.52 |
| Diameter Gas |
mm (inches) |
15.88 |
| Max.Length Out-In |
m |
30 |
| Max.Height Out-In |
m |
15 |
| Type (Cooling) |
| Indoor Unit |
| PLY-SP36EA |
| Outdoor Unit |
| SUY-SA36VA2 |
| Performance Parameters |
| Nominal Capacity |
3 Tr |
| Cooling Capacity(Min-Max) |
10.6(4.0-10.6)kW |
| Total Input |
3.52kW |
| Power Supply(Indoor) |
1ph 220-240V 50Hz |
| Power Supply(Outdoor) |
3ph 380-415V 50Hz |
| ISEER(W/W) |
4.30 |
| EER (W/W) |
3.01 |
| Air Flow Volume(CFM)(Low/Med2/Med1/High)-Indoor |
740/885/990/1095 |
| Air Flow Volume(CFM)-Outdoor |
2648 |
| Guaranteed Operating Range Upper Limit(DB) |
52 |
| Guaranteed Operating Range Lower Limit(DB) |
18 |
| Compressor, Refrigerant & Ambient Operations |
| Noise Level Indoor (Low/Med2/Med1/High) In dB(A) |
32/37/41/43 |
| Noise Level Outdoor In dB(A) |
52 |
| Refrigerant |
R410A |
| Dimensions & Weight |
| Indoor unit |
Dimensions (H x W x D)(panel) |
mm |
298(40)x840(950)
x840(950)
|
| Weight(panel) |
kg |
27(5) |
| Outdoor unit |
Dimensions (H x W x D) |
mm |
981x1050x330 |
| Weight |
kg |
65 |
| Ext.Piping |
Diameter Liquid |
mm (inches) |
9.52 |
| Diameter Gas |
mm (inches) |
15.88 |
| Max Piping length |
m |
50 |
| Max. height difference |
m |
30 |
| Type (Cooling) |
| Indoor Unit |
| PLY-SP42EA |
| Outdoor Unit |
| SUY-SA42VA2 |
| Performance Parameters |
| Nominal Capacity |
3.5 Tr |
| Cooling Capacity(Min-Max) |
12.3(6.1-12.3)kW |
| Total Input |
4.30kW |
| Power Supply(Indoor) |
1ph 220-240V 50Hz |
| Power Supply(Outdoor) |
3ph 380-415V 50Hz |
| ISEER(W/W) |
3.92 |
| EER (W/W) |
2.86 |
| Air Flow Volume(CFM)(Low/Med2/Med1/High)-Indoor |
740/885/990/1130 |
| Air Flow Volume(CFM)-Outdoor |
2648 |
| Guaranteed Operating Range Upper Limit(DB) |
52 |
| Guaranteed Operating Range Lower Limit(DB) |
18 |
| Compressor, Refrigerant & Ambient Operations |
| Noise Level Indoor (Low/Med2/Med1/High) In dB(A) |
32/37/41/44 |
| Noise Level Outdoor In dB(A) |
53 |
| Refrigerant |
R410A |
| Dimensions & Weight |
| Indoor unit |
Dimensions (H x W x D)(panel) |
mm |
298(40)x840(950)
x840(950)
|
| Weight(panel) |
kg |
27(5) |
| Outdoor unit |
Dimensions (H x W x D) |
mm |
981x1050x330 |
| Weight |
kg |
73 |
| Ext.Piping |
Diameter Liquid |
mm (inches) |
9.52 |
| Diameter Gas |
mm (inches) |
15.88 |
| Max Piping length |
m |
50 |
| Max. height difference |
m |
30 |
| Type (Cooling) |
| Indoor Unit |
| PLY-SP48EA |
| Outdoor Unit |
| SUY-SA48VA2 |
| Performance Parameters |
| Nominal Capacity |
4 Tr |
| Cooling Capacity(Min-Max) |
14.1(7.0-14.1)kW |
| Total Input |
6.02kW |
| Power Supply(Indoor) |
1ph 220-240V 50Hz |
| Power Supply(Outdoor) |
3ph 380-415V 50Hz |
| ISEER(W/W) |
3.54 |
| EER (W/W) |
2.34 |
| Air Flow Volume(CFM)(Low/Med2/Med1/High)-Indoor |
850/920/1025/1130 |
| Air Flow Volume(CFM)-Outdoor |
3071 |
| Guaranteed Operating Range Upper Limit(DB) |
52 |
| Guaranteed Operating Range Lower Limit(DB) |
18 |
| Compressor, Refrigerant & Ambient Operations |
| Noise Level Indoor (Low/Med2/Med1/High) In dB(A) |
36/39/42/44 |
| Noise Level Outdoor In dB(A) |
56 |
| Refrigerant |
R410A |
| Dimensions & Weight |
| Indoor unit |
Dimensions (H x W x D)(panel) |
mm |
298(40)x840(950)
x840(950)
|
| Weight(panel) |
kg |
27(5) |
| Outdoor unit |
Dimensions (H x W x D) |
mm |
981x1050x330 |
| Weight |
kg |
73 |
| Ext.Piping |
Diameter Liquid |
mm (inches) |
9.52 |
| Diameter Gas |
mm (inches) |
15.88 |
| Max Piping length |
m |
50 |
| Max. height difference |
m |
30 |