High Static pressure type

Specifications

Model PEFY-P40VMHS-E PEFY-P50VMHS-E PEFY-P63VMHS-E PEFY-P71VMHS-E PEFY-P80VMHS-E PEFY-P100VMHS-E PEFY-P125VMHS-E PEFY-P140VMHS-E
Power source 1-phase 220-230-240 V 50/60 Hz
Cooling capacity kW 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0
BTU/h 15400 19100 24200 27300 30700 38200 47800 54600
  Power input kW 0.055 0.090 0.075 0.090 0.160 0.190
  Current input (220-230-240 V) A 0.41-0.39-0.38 0.64-0.62-0.59 0.54-0.52-0.50 0.63-0.61-0.58 1.05-1.01-0.96 1.24-1.19-1.14
Heating capacity kW 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0
BTU/h 17100 21500 27300 30700 34100 42700 54600 61400
  Power input kW 0.055 0.090 0.075 0.090 0.160 0.190
  Current input (220-230-240 V) A 0.41-0.39-0.38 0.64-0.62-0.59 0.54-0.52-0.50 0.63-0.61-0.58 1.05-1.01-0.96 1.24-1.19-1.14
External finish Galvanized steel plate
External Dimension
H x W x D
mm 380x745x900 380 x 1,030 x 900 380 x 1,195 x 900
in 15 x 29-3/8 x 35-7/16 15 x 40-9/16 x 35-7/16 15 x 47-1/16 x 35-7/16
Net Weight kg(lbs) 35 (78) 45 (100) 51 (113) 53 (117)
Heat exchanger Cross fin(Aluminium plate fin and copper tube)
Fan Type x Quantity Sirocco fan x 1 Sirocco fan x 2
Airflow rate
 
cfm 353-424-494 477-565-671 547-636-777 636-759-883 936-1,130-1,342 989-1,201- 1,412
External static pressure Pa 50-100-150-200
mmH2O 5.1-10.2-15.3-20.4
Motor Type DC motor
Motor output 0.121 0.244 0.375
Air filter Option:Synthetic fiber unwoven cloth filter (long life filter) and filter box are recommended.
Refrigerant
piping diammeter
Gas(R410A) mm(in) 12.7(1/2) Brazed 15.88(5/8) Brazed
Liquid(R410A) mm(in) 6.35(1/4) Brazed 9.52(3/8) Brazed
Feild drain pipe diameter mm(in) O.D. 32(1-1/4)
Sound pressure level
(measured in anechoic room)
  (Low-Mid-High)
dB(A) 20-23-27 24-27-32 24-26-30 25-27-30 27-31-34 27-32-36
Model PEFY-P200VMH-E PEFY-P250VMH-E PEFY-P200VMHS-E PEFY-P250VMHS-E
Power source 3-phase 380-415V 50Hz/3N ~ 380-415V 60Hz 1-phase 220-240V 50Hz/1-phase 220-240V 60Hz
Cooling capacity kW 22.4 28.0 22.4 28.0
BTU/h 76400 95500 76400 95500
Heating capacity kW 25.0 31.5 25.0 31.5
BTU/h 85300 107500 85300 107500
Power
consumption
Cooling kW 0.99/1.14 1.23/1.41 0.63 *2 0.82 *2
Heating kW 0.99/1.14 1.23/1.41 0.63 *2 0.82 *2
Dimension
H x W x D
mm 470x1250x1120 470x1250x1120
in 18-9/16×49-1/4×44-1/8 18-9/16×49-1/4×44-1/8
Current Cooling 380-415V A 1.62/1.86 2.00-2.30
220-230-240V A 3.47-3.32-3.18 *2 4.72-4.43-4.14 *2
Heating 380-415V A 1.62/1.86 2.00-2.30
220-230-240V A 3.47-3.32-3.18*7 4.724.43-4.14*7
Net Weight kg(lbs) 100(221) 97(214) 100(221)
Heat exchanger Cross fin(Aluminium plate fin and copper tube)
Fan Type x Quantity Sirocco fan x 2 Sirocco fan x 2
Airflow rate cfm 2048 2543
1766-2154-2542(Lo-Mid-Hi) 2048-2507-2966(Lo-Mid-Hi)
External static pressure 380V Pa 110 · 220 *6
400-415V Pa 130 · 260 *6
Pa 50-100-150-200-250 *9
mmH2O 5.1-10.2-15.3-20.4-25.5 *9
Motor Type 3-phase induction motor DC motor
Output kW 0.76 *7 1.08 *7 0.87
Air filter(option) Synthetic fiber unwoven cloth filter(long life) Synthetic fiber unwoven cloth filter(long life filter) and filter box are recommended
Refrigerant
pipe diammeter
Gas
(Brazing)
mm(in) 19.05(3/4) 22.2(7/8) 19.05(3/4) 22.2(7/8)
Liquid
(Brazing)
mm(in) 9.52(3/8) 9.52(3/8)
Field drain pipe diameter mm(in) O.D. 32(1-1/4) O.D. 32(1-1/4)
Sound pressure level 380V dB(A) 42(110Pa)/45(220Pa) *8 50(110Pa)/52(220Pa) *8
400,415V dB(A) 44(130Pa)/47(260Pa) *8 52(130Pa)/54(260Pa) *8
Lo-Mid-Hi dB(A) 36-39-43 *10 39-42-46 *10
  • *1 Nominal cooling conditions Indoor: 27?CD.B./19?CW.B. (81?FD.B./66?FW.B.), Outdoor: 35?CD.B. (95?FD.B.) Pipe length: 7.5 m (24-9/16 ft.), Level difference: 0 m (0 ft.)
  • *2 The values are measured at the factory setting of external static pressure.
  • *3 Nominal heating conditions Indoor: 20?CD.B. (68?FD.B.), Outdoor: 7?CD.B./6?CW.B. (45?FD.B./43?FW.B.) Pipe length: 7.5 m (24-9/16 ft.), Level difference: 0 m (0 ft.)
  • *4 The factory setting of external static pressure is shown without < >. Refer to “Fan characteristics curves”, according to the external static pressure, in DATA BOOK for the usable range of air flow rate.
  • *5 Cooling/heating capacity indicates the maximum value at operation under the following condition. Cooling Indoor : 27°C(81°F)DB/19°C(66°F)WB, Outdoor : 35°C(95°F)DB Heating Indoor : 20°C(68°F)DB, Outdoor : 7°C(45°F)DB/6°C(43°F)WB
  • *6 The external static pressure is set to 220Pa (at 380V) /260Pa (at 400, 415V) at factory shipment.
  • *7 The value are that at 415V.
  • *8 It is measured in anechoic room.
  • *9 The rated external static pressure is shown without < >. The factory setting is the rated value.
  • *10 It is measured at the rated external static pressure in anechoic room.