Air Conditioning Systems – Royaal Engineers https://royaalgroups.com Best AC Service in TamilNadu | Best Refrigeration Services in TamilNadu | Mitsubishi Dealer in TamilNadu Thu, 08 Jul 2021 10:19:23 +0000 en-US hourly 1 https://wordpress.org/?v=6.9.1 https://royaalgroups.com/wp-content/uploads/2021/02/ROYAL-ENGINEERS_RED-150x150.png Air Conditioning Systems – Royaal Engineers https://royaalgroups.com 32 32 Eco https://royaalgroups.com/product/eco/ Thu, 08 Jul 2021 10:19:23 +0000 https://royaalgroups.com/?post_type=product&p=24312 Controller
Microprocessor based intelligent controller for precise control

Efficient Heat Exchanger

With Super Slit Fins and Inner Grooved Copper Tubes

Scroll compressors

High volumetric efficiency, Low power consumption, compact size with low noise

Propeller Fan

The largest ODU Fan in its category that delivers high airflow which maintains high COP even at high ambient temperatures

Space Creator

The low height indoor unit design gives you 20% more vertical space for your ceiling designs

Part Load Operation

Energy saver, provides redundancy, reduces wear and tear, prevents over cooling

High ambient design for 52 degree C Outdoor Air temperature

optimum cooling capacity, low deraton, high COP
]]>
Takumi https://royaalgroups.com/product/takumi/ Thu, 08 Jul 2021 10:11:39 +0000 https://royaalgroups.com/?post_type=product&p=24304 Part Load Operation
When the room temperature is close to the set temperature, the microprocessor shuts off the compressors automatically in a phased manner.

Phase Starting of Multiple Units

Takumi series comes with inbuilt solution to provide a time delay in starting up of compressors when multiple machines are switched on.

Group Control with central station

A unique enhancement that controls and monitors multiple ducted (up to 16 max)units with a single central controller. It can be placed anywhere in the air conditioner space.

Advance MicroProcessor Control

The Intelligent Microprocessor integrated in the controller of Takumi Series provides protection against various malfunctions that can hamper the overall health and functioning of the machine.

Phase Starting of Compressor

The microprocessor embedded in controller provides a delay of 15 seconds between the start-up of compressors of the same machine.

Other Features

  • UV Lamp with ventilation
  • Drain pump assembly
  • LCD remote control
  • Eco-friendly refrigerant (R410A)
  • Variable speed condenser fan motor
  • Tropical temperature
]]>
Non-inverter https://royaalgroups.com/product/24296/ Thu, 08 Jul 2021 07:24:46 +0000 https://royaalgroups.com/?post_type=product&p=24296
Model NameTotal Capacity
PL-P36BAKLCM 3 TR
PL-P42BAKLCM 3.5 TR
PL-P48BAKLCM 4 TR
]]>
Type (Cooling)
Indoor Unit
PL-P36BAK
Outdoor Unit
PU-P36YAKD
Performance Parameters
Nominal Capacity (Tr) 3 Tr
Power Supply(Indoor Unit) 1ph 220-240V 50Hz
Power Supply(Outdoor Unit) 3ph 380-415 V 50 Hz
Cooling Capacity 10.4kW
Total Input*2 3.37kW
EER(W/W) 3.59
Air Flow Volume(CFM)(Low/Med2/Med1/High)-Indoor 705/850/955/1060
Air Flow Volume(CFM)-Outdoor 3350
Guaranteed Operating Range Upper Limit(DB) 45
Guaranteed Operating Range Lower Limit(DB) 20
Compressor, Refrigerant & Ambient Operations
Noise Level Indoor (Low/Med2/Med1/High) In dB(A) 33/37/40/43
Noise Level Outdoor In dB(A) 54
Refrigerant R410A
Dimensions & Weight
Indoor unit Dimensions(Panel) (H x W x D) mm 298(35)x840(950)

x840(950)

Weight(Panel) kg 25(6)
Outdoor unit Dimensions (H x W x D) mm 1258x870x295
Weight kg 85
Ext.Piping Diameter Liquid mm (inches) 9.52
Diameter Gas mm (inches) 15.88
Max. height difference m 30
Max. piping length m 30
]]>
MS-GS https://royaalgroups.com/product/ms-gs/ Wed, 07 Jul 2021 12:16:55 +0000 https://royaalgroups.com/?post_type=product&p=24294
Model NameTotal Capacity
Ms-Gs10Vf 0.8 TR
Ms-Gs13Vf 1.0 TR
Ms-Gs18Vf 1.5 TR
Ms-Gs24Vf 1.9 TR
]]>
Type (Cooling)
Indoor Unit
MS-GS10VF
Outdoor Unit
MU-GS10VF
Performance Parameters
Capacity (Tr) 0.80 Tr
Star Rating – As Per BEE 3 Star
Power Supply 230 V / 50 Hz / Single Phase
Capacity (Rated) 2.65 kW
Total Input (Rated) 0.75 kW
ISEER 3.53
Operating Current Rated(A) 3.4
Air Volume (CFM) Indoor Unit(Silent-Low-Mid-Hi-SHi) 162/212/311/424
Compressor, Refrigerant & Ambient Operations
SPL Indoor Unit(Silent-Low-Mid-Hi-SHi) dB(A) 26/33/40/47
Refrigerant R32
Dimensions & Weight
Indoor unit Dimensions (H x W x D) mm 290x799x232
Weight kg 9.0
Outdoor unit Dimensions (H x W x D) mm 525x718x255
Weight kg 24.5
Ext.Piping Diameter Liquid mm (inches) 6.35(1/4)
Diameter Gas mm (inches) 9.52(3/8)
Max.Length Out-In m 20
Max.Height Out-In m 10
]]>
Kirigamine (MSY-RJS) https://royaalgroups.com/product/kirigamine-msy-rjs/ Wed, 07 Jul 2021 11:46:09 +0000 https://royaalgroups.com/?post_type=product&p=24292
Model NameTotal Capacity
MSY-RJS13VF 1.0TR
MSY-RJS15VF 1.25 TR
MSY-RJS18VF 1.5 TR
MSY-RJS22VF 1.9 TR
]]>
Type (Cooling)
Indoor Unit
MSY-RJS13VF
Outdoor Unit
MUY-RJS13VF
Performance Parameters
Capacity (Tr) 1.0 Tr
Star Rating – As Per BEE 4 Star
Power Supply 230 V / 50 Hz / Single Phase
Capacity (Rated Min-Max) 3.6 (0.9-3.7)kW
Total Input (Rated Min-Max) 1.27 (0.30-1.35)kW
ISEER 4.15
Operating Current Rated(A) 6
Air Volume (CFM) Indoor Unit(Silent-Low-Mid-Hi-SHi) 190/247/331/397/452
Compressor, Refrigerant & Ambient Operations
SPL Indoor Unit(Silent-Low-Mid-Hi-SHi) dB(A) 22/28/36/40/43
Refrigerant R32
Dimensions & Weight
Indoor unit Dimensions (H x W x D) mm 280x838x228
Weight kg 8.5
Outdoor unit Dimensions (H x W x D) mm 538x699x249
Weight kg 21
Ext.Piping Diameter Liquid mm (inches) 6.35(1/4)
Diameter Gas mm (inches) 9.52(3/8)
Max.Length Out-In m 20
Max.Height Out-In m 12
]]>
Floor Standing Exposed https://royaalgroups.com/product/floor-standing-exposed/ Mon, 22 Feb 2021 11:27:11 +0000 https://royaalgroups.com/?post_type=product&p=23993 Model Name PFFY-P VKM PFFY-P VLEM PFFY-P YM/PFFY-P YMH ]]>
Model PFFY-P20VKM PFFY-P25VKM PFFY-P32VKM PFFY-P40VKM
Power source 1-phase 220-240V 50Hz
Cooling capacity *1 kW 2.2 2.8 3.6 4.5
*1 BTU/h 7,500 9,600 12,300 15,400
Heating capacity *1 kW 2.5 3.2 4.0 5.0
*1 BTU/h 8,500 10,900 13,600 17,100
Power consumption Cooling kW 0.025 0.025 0.025 0.028
Heating kW 0.025 0.025 0.025 0.028
Current Cooling A 0.20 0.20 0.20 0.24
Heating A 0.20 0.20 0.20 0.24
External finish Plastic (Pure white)
Dimension H x W x D mm 600 x 700 x 200
in. 23-5/8 x 27-9/16 x 7-7/8
Net weight kg (lbs.) 15 (34)
Heat exchanger Cross fin (Alminium plate fin and copper tube)
Fan Type x Quantity Line flow fan x 2
Airflow rate*2 (Lo-Mid-Hi-SHi) m3/min 5.9-6.8-7.6-8.7 6.1-7.0-8.0-9.1 6.1-7.0-8.0-9.1 8.0-9.0-9.5-10.7
External static pressure Pa 0
Motor Type DC motor
Output kW 0.03 x 2
Air filter PP honeycomb fabric (Catechin Filter)
Refrigerant pipe diameter Gas (Flare) mm (in.) ø12.7 (ø1/2)
Liquid (Flare) mm (in.) ø6.35 (ø1/4)
Field drain pipe diameter mm (in.) I.D.16 (5/8)
Sound pressure level (Lo-Mid-Hi-SHi)*2 dB (A) 27-31-34-37 28-32-35-38 28-32-35-38 35-38-42-44
]]>
PAR-U02MEDA https://royaalgroups.com/product/par-u02meda/ Mon, 22 Feb 2021 11:16:48 +0000 https://royaalgroups.com/?post_type=product&p=24052 Touch Panel & Backlit LCD The operation settings screen is a touch panel. When the backlight is off, touching the panel turns on the backlight. The backlight will remain on for a preset length of time.
LED Indicator The color of the LED indicator indicates operation status. The LED indicator is lit during normal operations, and is not lit when units are stopped. In case of error, the indicator blinks.
Occupancy Sensor The occupancy sensor detects when the room is empty and provides energy-saving control.
Brightness Sensor The brightness sensor detects brightness in the room and provides energy-saving control.
Temperature & Humidity Sensor The sensor detects room temperature and relative humidity.
Automatic Turning Off Mitsubishi Electric remote controller has an occupancy sensor to automatically turn off the air conditioner when the room is empty.
Temperature Display LCD temperature setting and display in 0.5°C increments.

]]>
PAR-40MAA https://royaalgroups.com/product/par-40maa/ Mon, 22 Feb 2021 11:15:23 +0000 https://royaalgroups.com/?post_type=product&p=24050 Backlit LCD Large, easy-to-see display Full-dot LCD display with large characters for easy viewing Contrast also adjustable
Night Setback When the room temperature goes outside of a certain range during the predetermined period, this function automatically starts heating or cooling operation to prevent dew condensation or an excessive temperature increase in the room.
Draft Reduction “Close” has been added to the manual vane angle selection. The air outlet can be closed to reduce drafts from the air conditioner.
Highlight Display The screen background can be set to black to suit the ambience of the room.
Temperature Display LCD temperature setting and display in 0.5°C increments.

]]>
PAR-21MAA https://royaalgroups.com/product/par-21maa/ Mon, 22 Feb 2021 11:13:58 +0000 https://royaalgroups.com/?post_type=product&p=24048 Weekly timer Up to 8 ON/OFF/temperature settings per day in one-minute increments. Setting kept in nonvolatile memory. No need to worry about resetting after a power failure.
LCD Display Dot Liquid Crystal Display
Temperature Display LCD temperature setting and display in 1°C /1°F increments.

]]>
PAR-CT01MAA-S https://royaalgroups.com/product/par-ct01maa-s/ Mon, 22 Feb 2021 11:12:16 +0000 https://royaalgroups.com/?post_type=product&p=24045 Touch Panel & User Friendly Large icons are easily visible on the full color touch panel display.
Flexibility Customized display, color of parameter and background, editable parameter on the initial display.
Temperature Display LCD temperature setting and display in 0.5°C increments.

]]>